Port clearings
- Firewalls should be configured that at least the following ports are not being blocked:
- Ports 3050 und 3051: | communication between Autopoll and the Firebird database server |
- Port 21: | Standard service port (FTP) of the card reader Hecstar |
- Port 80: | Standard service port (HTTP) for example for MTS-K price reporting to Autopoll |
- Port 50835: | Standard service port of the card reader Heconomy |
- Port 950: | Default service port of a comport server MOXA |
- Port 4001: | Default service port of a comport server Opengear/ACM |
- Port 8000: | Default service port of a comport server W&T |
- Port 4500: | Default service port of a Mineo-probe polling device (polling as card reader via TCP/IP) |
Security features
- All security features (e.g. anti virus software, process scanning software etc.) have to be configured that at least the Autopoll database (with Autopoll V4 = APV4.GDB) is being excluded. Better would be the whole AutopollV4 folder and the whole firebird folder.
Windows system recovery
- The Windows system recovery has to be deactivated or has to be configured that the Autopoll database (with Autopoll V4 = APV4.GDB) and/or the file ending GDB is being excluded.